Fiber numerical aperture helps you match a light source, a multimode fiber and the receiving optics. For a custom fiber optic bundle, the useful question is how the launch cone and illuminated spot fit the actual fiber cores.

Quick answer

For a step-index multimode fiber, NA = n0 sin θmax, where θmax is the acceptance half-angle measured from the fiber axis and n0 is the refractive index outside the input face. In air, a 0.22 NA corresponds to a half-angle of about 12.7°. Specify NA together with wavelength, core size, end-face geometry, launch conditions and an agreed throughput test.

What is numerical aperture in optical fiber?

Numerical aperture is dimensionless. In the geometrical model of a step-index multimode fiber, it describes the range of launch angles that can support guided rays. With a core index ncore and cladding index nclad, the familiar expression is NA = √(ncore² − nclad²). The Thorlabs step-index NA tutorial explains this relationship and the external-medium term.

The acceptance angle is a half-angle. A drawing that states “25° acceptance” without saying whether this is a half-angle or full cone can lead to an incorrect optical design. Identify the surrounding medium and wavelength with the value. The visible metal ferrule diameter is a mechanical dimension; it does not define the usable optical core area.

Multimode fiber acceptance cone with incident rays and fiber axis used to define the numerical aperture half-angle
Figure 1. Conceptual step-index multimode ray model. Measure the acceptance half-angle from the fiber axis. The geometry is illustrative.

How to calculate the acceptance angle from NA

For an air launch, use θmax = arcsin(NA), taking n0 ≈ 1. These are design calculations, not specifications for an Opticlumos product.

Assumed fiber NAAcceptance half-angle in airFull cone angleDrawing note
0.126.9°13.8°Use the stated wavelength and launch medium
0.2212.7°25.4°Identify half-angle and full angle separately
0.3923.0°45.9°Check the receiving optics as well as the source

For example, suppose a proposed illumination bundle uses 0.22 NA multimode fibers in air. A 10° launch half-angle lies inside the ideal 12.7° cone. A 16° half-angle overfills that cone. This comparison flags angular mismatch; it does not calculate the fraction of power accepted. That fraction also depends on the source’s angular intensity distribution and its spatial overlap with the cores.

Matching a light source to a fiber optic bundle

1. Check the launch cone and focused spot together

Record the beam diameter or illuminated area at the input face, the launch angle distribution and the intended working distance. A beam can have a suitable angle but miss much of the core area. A bundle face also contains cladding and packing gaps. For a bifurcated bundle, mark which fiber groups belong to each branch so the illuminated area matches the intended route.

2. Check collection at the other end

Identify the receiving lens, detector or spectrometer interface and the usable aperture at its working distance. Ask for a throughput measurement using the planned launch and collection geometry. Avoid treating a fiber’s NA as a guarantee of the emitted power distribution after every possible cable length, bend and mode launch.

3. Use a different model for single-mode coupling

For a single-mode or PM fiber assembly, mode-field diameter and overlap with the incident optical mode are central coupling parameters. The simple multimode acceptance cone is insufficient. The Thorlabs fiber coupling insights discuss why NA-based ray estimates and single-mode coupling need different treatment. Use the PM fiber selection guide when polarization preservation is part of the requirement.

Three fiber bundle coupling checks covering launch angle, focused spot on usable core area and receiving optics
Figure 2. A 0.22 NA example connects an angle calculation to practical source, face and receiver checks.

What to include in an NA and bundle RFQ

RequirementInformation to sendAcceptance record
Optical bandOperating wavelengths, source type and optical powerMeasurement wavelength and source settings
Fiber constructionCore/cladding dimensions, NA target and tolerance, fiber materialAgreed fiber data and applicable measurement definition
End-face layoutActive area, packing arrangement, common-end and branch mapDrawing revision, face dimensions and branch identification
Mechanical routeLength, branch lengths, ferrules, jacket, temperature and bendsRoute and handling conditions used during testing
ThroughputInput reference plane, launch spot and cone, receiver apertureMeasured output/input ratio under the approved setup

Keep a sample approval record with the same optical setup intended for repeat orders. If the measured throughput changes, first compare the source alignment, end-face condition and receiving aperture. The attenuation guide helps separate loss quantities, while the bend-radius guide supports the routing review.

Frequently asked questions

Is a higher NA always better for a fiber bundle?

The useful value depends on the source and receiver. A wider acceptance cone can help collect angularly distributed light, but NA alone cannot establish coupled power, output beam suitability or transmission over the operating band.

Is the acceptance angle the full cone angle?

In NA = n0 sin θmax, θmax is the half-angle from the axis. The full cone is 2θmax. State the convention explicitly on the optical drawing.

Can I specify only NA when requesting a quote?

Include wavelength, core and face dimensions, branch layout, terminations and the mechanical route. For a throughput requirement, define both the launch and collection setup so the sample and production checks are comparable.

Match your source to a buildable fiber bundle

Send the wavelength band, launch spot and angle, active face size, branch drawing and receiving interface. Opticlumos can review the configuration and prepare an assembly quotation.

Request a bundle configuration review