Cross-section of a 900 micrometre ETFE optical fiber protection tube
Product structure from the technical catalog; schematic, not to scale.
Special Optical Cable · Fiber Protection

900 µm ETFE Fiber Protection Tube

A 900 µm ETFE fiber protection tube is a fluoropolymer tube designed to protect 250 µm optical fiber. The reference design has a 500 ± 50 µm inner diameter, a 900 ± 50 µm outer diameter and a listed operating range of -40 to +150°C.

Opticlumos supplies ETFE fiber tubing for engineers specifying protective components in custom optical cable assemblies. This product is a protection tube, not a complete jacketed cable or a temperature-sensing system. Fiber coating, termination and assembly limits must be evaluated separately.

Request Specifications & Quote

Product Features

Compact protective geometry

A nominal 0.5 mm bore inside a 0.9 mm outside diameter provides space for the specified 250 µm fiber. Confirm the fiber loading method and dimensional tolerances.

ETFE fluoropolymer material

Ethylene tetrafluoroethylene copolymer provides heat-resistant, electrically insulating protection. Material selection must be checked against the complete service environment.

Temperature-specific selection

The catalog lists -40 to +150°C operation, -40 to +70°C storage and -20 to +50°C installation. These are different limits, not interchangeable ratings.

Custom dimensions and identification

Other diameters, colors and delivery lengths can be reviewed against your drawing and order requirements.

Product Specifications

900 µm ETFE Fiber Protection Tube — catalog reference values
CharacteristicUnitSpecification
Inner diameterµm500 ± 50
Outer diameterµm900 ± 50
Intended optical fiber diameterµm250
Concentricity%<6.0
Non-circularity%<3.0
Material—Ethylene tetrafluoroethylene copolymer (ETFE)
Heat shrinkage at 85°C for 4 hours%≤3.0
Bending modulusMPa641.1 (ASTM D790)
Tensile strength at 23°CMPa37.9 (ASTM D1708)
Elongation at break at 23°C%300 (ASTM D1708)
Melting point°C+220 to +255 (ASTM D3159)
Limiting oxygen index%34 (ASTM D2863)
Operating temperature°C-40 to +150
Storage temperature°C-40 to +70
Installation temperature°C-20 to +50
Recommended delivery lengthkm3 or 4; other lengths on request

Reference values apply to the catalog protection-tube design. The melting point is not a continuous operating rating. The catalog also lists UL94 V-0 and RoHS material information; request supporting documentation for your selected material and order. This does not establish a fire rating or certification for a finished cable assembly. Final specifications and acceptance criteria are subject to order confirmation.

Applications & Selection

  • Protection of 250 µm fiber within a custom optical assembly
  • High-temperature fiber-routing designs subject to assembly qualification
  • Compact optical device leads requiring electrical insulation

Information to Include in Your RFQ

Specify the fiber coating and diameter, tube bore and outside diameter, continuous and peak temperatures, exposure duration, installation temperature, length and color. Confirm chemical exposure, bending, shrinkage and the requirements of connectors or adhesives. Do not apply the tube’s 150°C limit automatically to the enclosed fiber or finished assembly.

Frequently Asked Questions

Is this a 900 µm optical fiber or an empty protection tube?

It is an ETFE protection tube with a nominal 900 µm outside diameter and 500 µm bore, intended to protect 250 µm optical fiber. Confirm whether your quotation requires tubing alone or a fiber-loaded assembly.

Does the +220 to +255°C melting point mean continuous operation at 220°C?

No. The catalog operating range is -40 to +150°C. The melting point describes a material property and must not be used as the operating limit.

Is this a DTS sensing cable?

No. It is a protective component. A distributed temperature sensing cable also requires a suitable optical fiber, cable construction, compatible interrogator and system-level qualification.

Can the tube be customized?

Other diameter specifications, colors and lengths can be reviewed. Send the required bore, outside diameter, tolerances, fiber type, environment and quantity for confirmation.

Related Products & Technical Guides

Specify Your ETFE Fiber Protection Tube

Send tube dimensions, fiber diameter, service temperatures, quantity and any material-document requirements for technical review.

Request Technical Review

Sales@opticlumos.com · WhatsApp +86 13871596508